 CORCOM Product Guide Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for General Purpose Applications for UL544 Health Care Equipment
J Series
Front View, All Models 6J4/6J4-2 Terminal View
UL Recognized CSA Certified
6HJ4-1/6HJ4-2 Terminal View
J Series
The most widely accepted of all the power entry modules, the J series combines an IEC connector, 2-voltage, or 4voltage selection, and a North American fuseholder. It features a compact snap-in design and a unique voltage selector card. J4 Models - This general purpose filter provides susceptibility protection from line-to-ground noise on the power line and acts as a high frequency "clean-up" filter for more complex emissions applications. HJ4 Models - This medical filter provides susceptibility protection without the leakage current associated with lineto-ground capacitors. Designed to allow equipment to meet UL544 medical specifications for patient care and non-patient care equipment, the HJ filter has a maximum leakage current of 2A at 120 VAC 60 Hz. See Appendix C for more information on medical applications and UL standards. Equipment rating labels and mounting clips for thicker panel widths are available as accessories. For more information on UL544 specifications, see Appendix C. Note: When using the models with an IEC connector, remember that the leakage current of the companion line cord, GA400, is more significant than that of the filter which may disqualify this line cord from use in patient care applications.
Voltage Selection
Unfiltered and Filtered Models
Open cover door and rotate fuse-pull lever to left. Select operating voltage by orienting voltage selection card, desired voltage on top left side. Push card firmly into module slot. Rotate fuse-pull lever back into normal position and re-insert fuse into holders. Use caution in selecting correct fuse value.
Unfiltered Models Part Number 6VJ1 6VJ1-2 Unfiltered Models Part Number 6VJ4 6J4-2 6HJ4-4 6HJ4-2 Available Voltage Selection RFI Filter Type Positions 4 General Purpose1 2 General Purpose1 4 Medical2 Medical2 2 Available Voltage Selection Positions 4 2
Note 1: General purpose filter for susceptibility applications Note 2: Medical line filter for very low leakage UL544 health care requirements
114
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for General Purpose Applications for UL544 Health Care Equipment (Continued)
J Series
Electrical Schematics
Filtered 6J4 & 6J4-2
Note 3 120V 100V A Hot Ground Power On-Off Off On Pilot light J H Note 1 B C D E F A B C D E
120V
Specifications
Maximum leakage current, each line-to-ground:
220V 240V
20V
@250 VAC 50 Hz: Hipot rating (one minute): line-to-ground VDC line-to-line VAC Operating frequency: Operating voltages: 6VJ1, 6J4, 6HJ4-4: 6J1-2, 6J4-2, 6HJ4-2: Rated current: Fuse (not included):
6J4 6EHJ4 Models Models 500 A 5 A
6VJ Models 5 A
100V
Power Entry Modules
Neutral
2250 1450
2250 1450
F Transformer primary
1550 1450 50/60 Hz
100, 120, 220, 240 VAC 115, 230 VAC 6A Integral fuseholder, line side,accepts .25" x 1.25" fuse
Filtered 6HJ4-4 & 6HJ4-2
Note 3 120V 100V A Hot Ground Power On-Off Off On Pilot light J H Note 1 B C D E F A B C D E
120V
220V 240V
20V
Terminals:
Connector block terminals .045" square, suitable for soldering, wire wrapping, or crimp-on lugs
100V
Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Rating J4 Models 6A HJ4 Models 6A .15 9 9 .5 20 11 Frequency-MHz 1 5 10 25 15 41 19 45 13 20 45 12 30 48 10
Neutral
F Transformer primary
Note 1: Note 2: Note 3:
Jumper required if only SPST power switch is used. Jumpers required if no input filtering is used. Use only 120V and 240V positions for 2-volt selection units.
115
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for General Purpose Applications for UL544 Health Care Equipment (Continued)
J Series
Case Styles
Unfiltered Models
Note 5 .110 [2.79] Terminals
Case Dimensions
Part No. Unfiltered 6VJ1/6VJ1-2 Filtered 6J4/6J4-2 6HJ4-4/6HJ4-2 A (max) 2.68 68.1 2.75 69.9 2.75 69.9 B (max) 1.52 38.6 1.87 47.5 1.87 47.5 C (max) 1.17 29.7 1.17 29.7 1.17 29.7 D (max) 1.23 31.2 1.58 40.1 1.58 40.1
C
A
D B
Filtered Models
.110 [2.79] Terminals Note 5
C
Recommended Panel Cutout
Unfiltered and Filtered Models
D B
Note 4
A
1.063* 27.0
1.17 29.7
Bezel
2.60* 66.0 2.68 68.1 3.00 76.2
Mounting diagram (Clearance)
*.003 Note 4: Note 5:
Fuse cover door shown in open condition. Standard units mount in panel thickness of .060 - .090" Special mounting clips sold separately for panel thickness of .105-.125". See Accessories List on next page.
116
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for General Purpose Applications for UL544 Health Care Equipment (Continued)
J Series
Equipment Rating Labels
Unfiltered and Filtered Models
Self-adhesive labels, as shown below, are available in multiples of 40. Specify part number.
2.330
Accessories
Unfiltered and Filtered Models
Line Cord No. GA400: (7 1/2 foot, 3-conductor line cord to mate with J series) JA302, 2 Voltage Selector Card (comes standard with 6VJ1-2, 6J4-2, 6HJ4-2)
100V 120V 220V 240V 500mA 250mA
4-Volt
.210
Line V. + 5 - 10% 48-440 - 50 VA Max.
Fuse
JA304, 4 Voltage Selector Card (comes standard with 6VJ1, 6J4, 6HJ4-4) JA403, Mounting Clips for .105-.125" Panel JA500, Voltage Selector Card Extractor Tool
Power Entry Modules
A
B
C
Part Number JA410 JA411 JA412 JA413 JA414 JA415 JA416 JA417 JA418 JA419
A B C VA Fuse Fuse Max. 100/120 (115) 220/240 (230) 25 250 mA 125 mA 50 500 mA 250 mA 100 1A 500 mA 200 2A 1A 250 2.5A 1.25A 300 3A 1.5A 400 4A 2A 500 5A 2.5A 600 6A 3A Assortment
JA410-JA418: 40 labels of one part number JA419: 5 each JA410 - JA418 (45 labels)
117
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com